Part Numbers 1306-W18 / 1306-W18-T

Features and Benefits
  • An efficient way to terminate wire to board;
  • No additional strain relief required;
  • No additional wire preparation required;
  • Available in taped format – no need for additional assembly equipment;
  • Additional wire gauges available. Consult Factory for details;
  • Can be terminated in the field with use of simple hand tool.
Loose Part No. 1306-W18
Taped Part No. 1306-W18-T (16mm Tape per EIA-481)
Wire Sizes 18 AWG (Solid or Stranded)
Insulation Outside Diameter 0.113 in. (2.87mm) Maximum
Material Thickness / Type .016in (0.406mm) Phos Bronze CDA 510
Standard Finish 100% Matte Tin over Copper (0)
Current Rating 15 Amperes
Feeder System Standard 16mm Tape Feeder for 1306-W18-T
Wire Termination Tools WIT-1306 (for low volume and/or field terminations)
U.S. Patent No. 9,255,079 B2
Zierick recommends 0.006" (0.15mm) stencil thickness for most applications. For other stencil thicknesses, call Zierick’s product development department.
Consult the factory for center-to-center spacing between adjacent terminals.